VT540 / Vibration sensor

Product page: https://vutlan.com/analog-sensors/19-vt540-vibration.html

Datasheet page: https://vutlan.atlassian.net/l/cp/jzDSR4KK

Function and purpose

Detects vibration. For installation on walls, windows, etc., the sensor controls vibration. For example, detects the breaking of the window by an intruder if installed on the window glass. 

Technical specifications

Feature
Description
Feature
Description

Sensor type

Analog sensor

Dimensions

60×18×18 mm

Weight

60 g

Input

RJ-12 / RJ-11 (6p4c)

Outputs

RJ11 / RJ12 (6p4c)

Operating temperature

-10 °C to +80 °C

Operating humidity

5% to 95% (Non-Condensing)

Mounting

The mounting bracket, sticker, and screws are included. Installed on the surface where possible vibration is possible. E.g. windows, doors, etc.

Power consumption

60mW

Max. distance m

150 m

HS Code

9025 11 800

Components

Manufactured in E.U.

Daisy chain possible

No

Package includes

Drawing

Connecting vibration sensor

The sensor uses a standard Vutlan analog RJS5 RJ11 sensor cable for connecting to the monitoring unit.  

Installation using a sticker and a bracket

Option 1.

There's a round bump at the bottom of the plastic enclosure of the sensor. It is used for fastening when the sensor is mounted on walls using a screw. In the current example, it is not needed. If you are planning to mount a device differently, do not follow this step.

Cut the round bump using a knife so that the bottom of a plastic enclosure will be flat.



Option 2.

a) Stick the mounting sensor to the surface using the sticker.

or

b) Stick a sensor to the surface using a screw.



Option 3.

Mount the sensor to the surface using a mounting bracket. The mounting bracket and the sensor can be either attached by the stickers or together with screws and nuts.

Analog sensor connection

Configuring the sensitivity of the sensor

The sensor is very sensitive. At times this may prove to be too sensitive. In this case, it is possible to lower the sensor's sensitivity:

1) Unplug the sensor from the cable.

2) Open the sensor cover using a flat screw.

3) Take the two-pin jumper header out. This will lower the sensitivity slightly.

4) Close the cover and plug the sensor back in.

If the sensitivity is still too high, Vutlan can produce a custom vibration sensor will a much lesser sensitivity on demand. In this case, please contact the sales team.

Sensor configuration

 


Copyright:

Vutlan s.r.o. (LLC)

Remote Infrastructure Monitoring and Control

43 ul.Svornosti, 821 06 Bratislava,

Slovak Republic

www.vutlan.com