Integration with 3rd party software and hardware
Children’s pages include:
Vutlan systems can communicate with 3rd party hardware and software. The table below shows some of such options.
Method | Description | Configuration link |
---|---|---|
SNMP (Simple Network Management Protocol) | Send data to your SNMP IT infrasstructure monitoring software, NMS (network managment software) software using an SNMP agent and sub-agents. | |
SNMP Get | Read data from external equipment via SNMP PDU GET (v2c) | |
SNMP Trap notification | Send a notification to one or more trap receivers onto a specified IP address | |
Vutlan open Rest-API (Application Programming Interface) | Allows two applications to talk to each other. API simplifies programming. Can be used for communication with your own applications/software. The query is sent as a HTTP POST request and consists of fields. The response from the server part to the client part is transmitted as a string in XML format. | |
Rest-API in JSON format | API requests in JSON format | |
HTTP request | Send an HTTP request to the specified server. | |
Modbus RTU | Used to read and write data from external equipment via Modbus RTU protocol using a twisted pair line (RS-485). Such equipment can be sensors/meters or devices/systems/units. | |
Modbus TCP/IP | Used to read and write data from external equipment via Modbus TCP protocol over LAN (local area network). Such equipment can be sensors/meters or devices/systems/units. enables communication among many devices connected to the same network | |
4-20mA sensors/meters |
| |
Sensors with outputs: 0-4V, 0-5V, 0-10V, 0-15V, 0-75V, |
| https://vutlan.atlassian.net/wiki/spaces/DEN/pages/558202882 |
12V DC, max 0,25mA devices | Connect low-current devices, (For example, alarm beacons, sirens, strobe and other). | |
12V DC, max 5A |
| https://vutlan.atlassian.net/wiki/spaces/DEN/pages/583237633 |
Dry contact inputs | Monitor voltage-free contacts For example HVAC (Heating, Ventilation, and Air Conditioning) units, BMS (battery monitoring systems), | https://vutlan.atlassian.net/wiki/spaces/DEN/pages/2687401997 |
Dry contact outputs | Optically isolated contacts can send a signal to a system/device/unit. | https://vutlan.atlassian.net/wiki/spaces/DEN/pages/edit-v2/2687402027 |
NO/NO/COM relays | Control x2 loads managed by built-in latching relays. Control AC/DC mains (lamps, fans, motors, or other devices.). | https://vutlan.atlassian.net/wiki/spaces/DEN/pages/335970311 |
RADIUS | Work with a centralized database for authentication (verification of authenticity) and authorization (determining access rights) of users. | |
Web SMS | Send messages through special services. Vutlan monitoring unit sends a request to such a service, which in return sends an SMS to the recipients, depending on the API in the request. | https://vutlan.atlassian.net/wiki/spaces/DEN/pages/612859918 |
RTSP IP cameras | Uses H.264 codec and records video on SATA HDD, SD card, or USB flash drive. | |
IP cameras | You can view IP cameras with JPEG / MJPEG video stream compression format. Record mode is not possible. | |
AV camera | Record videos on SATA drive. | https://vutlan.atlassian.net/wiki/spaces/DEN/pages/1280147477 |
USB cameras | You can view and record USB webcams of the UVC standard with support for hardware compression in MJPEG | https://vutlan.atlassian.net/wiki/spaces/DEN/pages/325779478 |