Comparison chart: PDUs VT604 & VT608
Device description | ||
---|---|---|
Description: | Switchable | Switchable |
Device management: Web, SNMP, manual using SMS, 4G LTE | Yes | Yes |
Sensor access: Three-level by login | Yes | Yes |
Interface and supported protocols | ||
LAN: Ethernet 10/100 Mbit | Yes | Yes |
OS: Linux | 3.10 | 3.10 |
Interface: Any browser | Yes | Yes |
Memory RAM: | 64Mb | 64Mb |
CPU Speed: | 300 MHz | 300 MHz |
Total CPU cores: | 1 | 1 |
Clock: Built-in clock | Yes | Yes |
Timer: Built-in watchdog | Yes | Yes |
The maximum amount of sensors: physical sensors, dry contacts, relays |
|
|
The maximum amount of elements: notifications, triggers, timers, logic, sensors, dry contacts, SNMP Get, SNMP Trap, Dial task, and other elements |
|
|
| ||
Networking / Protocol support | ||
LTE Gateway mode: Internet access (routing for internal network) (modem ordered separately) | Yes | Yes |
LTE Access mode: Internet access over LTE (modem ordered separately) |
|
|
Network protocols: DHCP; HTTP; HTTPS; SNMP v1, v2c, v3; SMTP; FTP; Syslog; TLS; | Yes | Yes |
Modbus RTU (only with USB converter) | Yes | Yes |
Modbus TCP / IP | Yes | Yes |
Static routing |
|
|
Dynamic DynDNS | Yes | Yes |
Access via RADIUS server | Yes | Yes |
VPN: secure data communications; secure change of connection between LTE and LAN | Yes | Yes |
SSL installation | Yes | Yes |
NTP server | Yes | Yes |
| ||
Alerts / Notifications | ||
Alert types: E-mail, FTP log, Syslog, SMTP, SNMP Traps, SMS (Modem is ordered separately), Web-to-SMS, | Yes | Yes |
A maximum number of "mail to" recipients in an E-mail notification: | 10 | 10 |
A maximum number of "SMS to" recipients in an SMS notification: also the maximum amount of phone numbers | 10 | 10 |
| ||
Virtual sensors | ||
Ping: Built-in pinging | Yes | Yes |
IP cameras: Connect the IP MJPEG camera with a proxy via the master module. Only view, no record. | 4 | 4 |
Get SNMP: Read data from external equipment via SNMP PDU GET (v1/2c) | Yes | Yes |
Logic schemes: Used to specify automatic actions to events that occur in the system. | Yes | Yes |
Timers: Allows you to plan the events in the system. | Yes | Yes |
Triggers: Generate events in the system if logic is triggered. | Yes | Yes |
SNMP traps | Yes | Yes |
Virtual Math element (combine several sensor data and calculate new data) | Yes | Yes |
Logic schemes | Yes | Yes |
Modbus TCP/IP: read/write | Yes | Yes |
Power | ||
Power supply: | 110-240V 50-60 Hz | 110-240V 50-60 Hz |
Input: | C14 10A | C20 16A |
Fuse: | 10A | 16A |
Outputs: | 4 | 8 |
Power consumption: | 10W | |
Total power load: | 2.4 kW | |
Power measurement: | No | No |
Outputs: Bistable relays with indication on the front panel | 4 | 8 |
Outputs | ||
Relays outputs: 12V 0.25A | 2 | 2 |
Bistable relays: with indication on the front panel | x4 Max 10A | x8 Max 10A |
Sockets: | 4 IEC 320 C13 | 8 IEC 320 C13 |
|
|
|
Inputs | ||
Analog port: 6P6C for connection of an analog sensor. (extendable using CAN bus) | 2 ports | 2 ports |
x1 CAN port: Max number of sensors Use CAN-12V-1A for connecting more than 12 devices. | 20 | 20 |
Max. dry contact inputs (contact closures/digital inputs) Extadable using CAN bus and Dry contacts unit | 2 built-in & extadable | 2 built-in & extadable |
|
|
|
Other connectors | ||
Ethernet port: 10/100Mbit | Yes | Yes |
Mini USB AB: USB 2.0 HS | Yes | Yes |
Switch Normal / Recovery: returns the device to factory settings | □ | Yes |
External memory / Logs | ||
USB flash drive: logs, sensor readings, item settings, etc. | Yes | Yes |
Send system log to e-mail: Logs, sensor data, elements settings, etc. | Yes | Yes |
Sensor dump files: save the per-second samples of analog and discrete sensors | Yes | Yes |
Yes | Yes | |
Send to FTP server: Logs, sensor data, elements settings, etc. | Yes | Yes |
Maximum amount of log files: 10,000 logs/days = 27 years | Yes | Yes |
Sample rate/period (logs, graphs) | 1 s | 1 s |
Modem (extension ordered separately) | ||
4G LTE modem: ordered separately. | ||
Modem modes:
| Access / SMS | Access / SMS |
|
|
|
Embedded onboard sensors | ||
Temperature sensor: +/- 1 °C Case temperature. | Yes | Yes |
Environmental characteristics | ||
Operating temperature: 0 to 60 °C | Yes | Yes |
Storage temperature: –25 to 85 °C | Yes | Yes |
Operating humidity: 0 to 90 %, non-condensing | Yes | Yes |
Storage humidity: 0 to 95 %, non-condensing | Yes | Yes |
Other Features | ||
Installation: | 19” | 19” |
Dimensions (L x W x H) in mm: | 440*44*80 | 440*44*80 |
Weight: | 1,3 kg | 1,5 kg |
External chassis grounding: M4 thread | Yes | Yes |
|
|
|
Web interface (panels) | ||
Dashboard panel: | Yes | Yes |
Overall statistics panel: | Yes | Yes |
System tree panel: sensors and devices displayed in a hierarchy | Yes | Yes |
Dry inputs panel: | Yes | Yes |
Event log panel: | 200 | 200 |
Logic schemes panel: | Yes | Yes |
Cameras panel: | Yes | Yes |
Map panel: 5 layers | Yes | Yes |
Users panel: | Yes | Yes |
CAN configuration panel: | Yes | Yes |
Graphs panel: | Yes | Yes |
Reset smoke detectors panel: | Yes | Yes |
Preferences panel: Web GUI, Network, Time, Logging, DynDNS, SNMP, RADIUS, FTP backup, VPN Clent, GPS, SMTP, Routing | Yes | Yes |
System menu panel: About, Firmware, Export, Support | Yes | Yes |
List of latest sent SMS messages: | 100 | 100 |
Analog sensor power reset: resets smoke sensors | Yes | Yes |