Comparison chart: Vutlan vs NetBotz APC

Comparison chart: Vutlan vs NetBotz APC

Used links include:

250 and 750 comparison chart:



●  Built-in       □  None       ♦ Extension possible       ◊ Not extendable



VT960ii

VT855i

VT825i

NetBotz 750

NetBotz 250

VT335i



VT960ii

VT855i

VT825i

NetBotz 750

NetBotz 250

VT335i

CPU speed:

1.2 Ghz

600mHz

600mHz

PowerPC

PowerPC

600mHz

RAM:

1Gb

128Mb

128Mb



64Mb

128Mb

OS: Linux

v.5.10

v.5.40

v.5.40





v.5.40



REMOTE CONTROL

VT960ii

VT855

VT825

NetBotz 750

NetBotz 250

VT335i

Device Management: SNMP

V.1-3

A single name, multiple users

V.1-3

A single name, multiple users

V.1-3

A single name, multiple users

V.1-3

Single user

V.1-3

Single user

V.1-3

A single name, multiple users

Device Management: Web Interface

Device Management: SMS



PROTOCOLS

VT960ii

VT855

VT825

NetBotz 750

NetBotz 250

VT335i

REST API:

Yes

Yes

Yes

Yes

Yes

Yes

Extension

CAN

CAN

CAN

LIN

LIN

CAN

DHCP, DNS, HTTP, HTTPS, TCP,

SSH

TCP/IP

SSL

SMTP

FTP

Modbus

VPN

RADIUS



INTERFACE

VT960ii

VT855

VT825i

NetBotz 750

NetBotz 250

VT335

Language:

Multi

Multi

Multi

English

English

Multi

Sensor data graphs:

Sensor data tables:

Max. amount of sensors: physical sensors, dry contacts, relays

288

148

148

78

+ 47 Zigbee

42

+ 47 Zigbee

148

Max. amount of elements: notifications, triggers, timers, logic, sensors, dry contacts, SNMP Get, SNMP Trap and other elements

2000

700

700





700

Max amount of extensions:

32 CAN devices

32 CAN devices

32 CAN devices

13 LIN expansion pods



32 CAN devices



ALERTS / NOTIFICATIONS

VT960ii

VT855

VT825

NetBotz 750

NetBotz 250

VT335

Alert type: E-mail

Alert type: SNMP

Alert types: FTP log, Syslog, SMTP, SNMP Traps, Web-to-SMS

Alert type: SMS

Alert type: Web-to-SMS





Alert type: Dial task





Alert type: HTTP request





Alert type: SMS link





Maximum number of "mail to" recipients in an E-mail notification:

100

15

15



4

15

Maximum number of "SMS to" recipients in an SMS notification:

100

10

10





10

Alarm beacon output:



SUPPORTED SENSORS

VT960ii

VT855

VT825

NetBotz 750

NetBotz 250

VT335

Temperature, Temp/Humidity, Door contact, Smoke, Spot leak, Vibration, Dry Contacts, PIR:

Rope Leak, 0-5V:

Airflow/Wind velocity, AC voltage, DC voltage, AC ampere meter, PIR, 4-20mA, Relay contact, Pressure:















VIRTUAL SENSORS

VT960ii

VT855

VT825

NetBotz 750

NetBotz 250

VT335

Dew point: Built-in function for humidity Dew point.

PINGs: Built-in function for server pinging. Test the reach-ability of a host on a network.

Get SNMP: Read data from external equipment via SNMP PDU GET (v1/2c)





User keys: Add users who have access using RFID reader.

Logic schemes: Used to specify automatic actions to events that occur in the system.





Timers: Allows you to plan the events in the system.

Triggers: Generate events in the system if logic is triggered.





Push notifications





SNMP traps

Virtual Math element (combine several sensor data and calculate new data)





Logic schemes





Groups:







POWER

VT960II

VT855

VT825

NetBotz 750

NetBotz 250

VT335

Power input:

90-230V

90-230V 

90-230V 

90-230V 

90-230V 

+12V 

Power input DC:

24 ÷ 48V 

24 ÷ 48V 

24 ÷ 48V 

 

Redundancy:

Fuse:  Fuse at the inlet

2A

1A