Comparison chart: Vutlan vs NetBotz APC
Used links include:
● Built-in □ None ♦ Extension possible ◊ Not extendable
VT960ii | VT855i | VT825i | NetBotz 750 | NetBotz 250 | VT335i | |
---|---|---|---|---|---|---|
CPU speed: | 1.2 Ghz | 600mHz | 600mHz | PowerPC | PowerPC | 600mHz |
RAM: | 1Gb | 128Mb | 128Mb | 64Mb | 128Mb | |
OS: Linux | v.5.10 | v.5.40 | v.5.40 | v.5.40 | ||
REMOTE CONTROL | VT960ii | VT855 | VT825 | NetBotz 750 | NetBotz 250 | VT335i |
Device Management: SNMP | V.1-3 A single name, multiple users | V.1-3 A single name, multiple users | V.1-3 A single name, multiple users | V.1-3 Single user | V.1-3 Single user | V.1-3 A single name, multiple users |
Device Management: Web Interface | ● | ● | ● | ● | ● | ● |
Device Management: SMS | ● | ● | ● | □ | □ | ● |
PROTOCOLS | VT960ii | VT855 | VT825 | NetBotz 750 | NetBotz 250 | VT335i |
REST API: | Yes | Yes | Yes | Yes | Yes | Yes |
Extension | CAN | CAN | CAN | LIN | LIN | CAN |
DHCP, DNS, HTTP, HTTPS, TCP, | ● | ● | ● | ● | ● | ● |
SSH | ● | ♦ | ♦ | ● | ● | ♦ |
TCP/IP | ● | ● | ● | ● | ● | ● |
SSL | ● | ● | ● | ● | ● | ● |
SMTP | ● | ● | ● | ● | ● | ● |
FTP | ● | ● | ● | ● | ● | ● |
Modbus | ● | ● | □ | ● | ● | □ |
VPN | ● | ● | ● | □ | □ | ● |
RADIUS | ● | ● | ● | ● | ● | ● |
INTERFACE | VT960ii | VT855 | VT825i | NetBotz 750 | NetBotz 250 | VT335 |
Language: | Multi | Multi | Multi | English | English | Multi |
Sensor data graphs: Sensor data tables: | ● | ● | ● | ● | ● | ● |
Max. amount of sensors: physical sensors, dry contacts, relays | 288 | 148 | 148 | 78 + 47 Zigbee | 42 + 47 Zigbee | 148 |
Max. amount of elements: notifications, triggers, timers, logic, sensors, dry contacts, SNMP Get, SNMP Trap and other elements | 2000 | 700 | 700 | 700 | ||
Max amount of extensions: | 32 CAN devices | 32 CAN devices | 32 CAN devices | 13 LIN expansion pods | 32 CAN devices | |
ALERTS / NOTIFICATIONS | VT960ii | VT855 | VT825 | NetBotz 750 | NetBotz 250 | VT335 |
Alert type: E-mail | ● | ● | ● | ● | ● | ● |
Alert type: SNMP | ● | ● | ● | ● | ● | ● |
Alert types: FTP log, Syslog, SMTP, SNMP Traps, Web-to-SMS | ● | ● | ● | ● | ● | ● |
Alert type: SMS | ● | ● | ● | □ | □ | ● |
Alert type: Web-to-SMS | ● | ● | ● | ● | ||
Alert type: Dial task | ● | ● | ● | ● | ||
Alert type: HTTP request | ● | ● | ● | ● | ||
Alert type: SMS link | ● | ● | ● | ● | ||
Maximum number of "mail to" recipients in an E-mail notification: | 100 | 15 | 15 | 4 | 15 | |
Maximum number of "SMS to" recipients in an SMS notification: | 100 | 10 | 10 | 10 | ||
Alarm beacon output: | ● | ● | ● | ● | ● | ● |
SUPPORTED SENSORS | VT960ii | VT855 | VT825 | NetBotz 750 | NetBotz 250 | VT335 |
Temperature, Temp/Humidity, Door contact, Smoke, Spot leak, Vibration, Dry Contacts, PIR: | ● | ● | ● | ● | ● | ● |
Rope Leak, 0-5V: | ● | ● | ● | ● | □ | ● |
Airflow/Wind velocity, AC voltage, DC voltage, AC ampere meter, PIR, 4-20mA, Relay contact, Pressure: | ● | ● | ● | □ | □ | ● |
VIRTUAL SENSORS | VT960ii | VT855 | VT825 | NetBotz 750 | NetBotz 250 | VT335 |
Dew point: Built-in function for humidity Dew point. | ● | ● | ● | ● | □ | ● |
PINGs: Built-in function for server pinging. Test the reach-ability of a host on a network. | ● | ● | ● | □ | □ | ● |
Get SNMP: Read data from external equipment via SNMP PDU GET (v1/2c) | ● | ● | ● | ● | ||
User keys: Add users who have access using RFID reader. | ● | ● | ● | ● | ● | ● |
Logic schemes: Used to specify automatic actions to events that occur in the system. | ● | ● | ● | ● | ||
Timers: Allows you to plan the events in the system. | ● | ● | ● | ● | ● | ● |
Triggers: Generate events in the system if logic is triggered. | ● | ● | ● | ● | ||
Push notifications | ● | ● | ● | ● | ||
SNMP traps | ● | ● | ● | ● | ● | ● |
Virtual Math element (combine several sensor data and calculate new data) | ● | ● | ● | ● | ||
Logic schemes | ● | ● | ● | ● | ||
Groups: | ● | ● | ● | ● | ||
POWER | VT960II | VT855 | VT825 | NetBotz 750 | NetBotz 250 | VT335 |
Power input: | 90-230V | 90-230V | 90-230V | 90-230V | 90-230V | +12V |
Power input DC: | 24 ÷ 48V | 24 ÷ 48V | 24 ÷ 48V | □ | □ | □ |
Redundancy: | ● | ● | ● | □ | □ | □ |
Fuse: Fuse at the inlet | 2A | 1A | 1A | □ | □ | □ |
Max. power consumption: | 30W | 10W | 10W | 15W | 55W | 10W |
The maximum current load on the relay: | 10А/250mА | 10А/250mА | 250mА | 1A/75ma | 1A/75ma | 250mA |
Power reservation: built-in voltage monitor, voltage range 9-12.6V. | ● | ♦ | ♦ | □ | □ | ♦ |
OUTPUTS | VT960ii | VT855 | VT825 | NetBotz 750 | NetBotz 250 | VT335 |
NC/NO/COM Relay outputs: | x2 | x2 | □ | x2 | x1 | □ |
Relay outputs / Beacon ports: | x2 12V 0.25A | x2 12V 0.25A | x2 12V 0.25A | x1 Beacon port x1 12V x1 24V | x1 Beacon port x1 12V x1 24V | x2 12V 0.25A |
Max. dry contact outputs (contact closures/digital outputs): | x8 | x8 | □ | □ | ||
Audio output: AV OUT | 1 | □ | □ | □ | □ | □ |
Video output: AV OUT | 1 | □ | □ | □ | □ | □ |
INPUTS | VT960ii | VT855 | VT825 | NetBotz 750 | NetBotz 250 | VT335 |
Sensor ports: | 8 | 8 | 8 | 12 | 4 | |
CAN / A-link: | CAN | CAN | CAN | LIN | LIN | CAN |
Wireless sensors: | 300 m ♦ | 300 m ♦ | 300 m ♦ | 30 m | 30 m | 300 m ♦ |
Dry contact IO: | x48 | x8-32 | x4-16 | □ | □ | 4 |
Modbus: | ● | ● | □ | ♦ | ● | □ |
Audio input: AV IN | 1 | □ | □ | □ | □ | □ |
Video input: AV IN | 1 | □ | □ | □ | □ | □ |
VIDEO | VT960ii | VT855 | VT825 | NetBotz 750 | NetBotz 250 | VT335 |
Video cameras: | AV, USB, TCP/IP | USB, TCP/IP | USB, TCP/IP | TCP/IP | □ | USB, TCP/IP |
Video power supply output: | ● | □ | □ | POE | □ | □ |
IP cameras: View? Record? Connect up to x4 IP JPEG cameras | x4 View only | x4 View only | x4 View only | up to x4 cameras Camera Pod 150 | x4 View only | |
OTHER CONNECTORS | VT960ii | VT855 | VT825 | NetBotz 750 | NetBotz 250 | VT335 |
Ethernet port (LAN): | x1 port 10/100 Mbit/s | x1 port 10/100 Mbit/s | x1 port 10/100 Mbit/s | x1 port 10/100/1000 Mbit/s | x1 port 10/100 Mbit/s | x1 port 10/100 Mbit/s |
PoE private network switch: private LAN | □ | □ | □ | 4* POE | □ | □ |
USB 2.0 Type A: | x1 | x1 | x1 | x2 | x1 | □ |
USB 2.0 Micro-A: ( | x1 | x1 | x1 | □ | □ | x1 |
SATA: SATA drive | ● | □ | □ | □ | □ | □ |
Shutdown button: Softly shuts down the device. | ● | □ | □ | □ | □ | □ |
STORAGE / MEMORY | VT960ii | VT855 | VT825 | NetBotz 750 | NetBotz 250 | VT335 |
96h for resolved alarms | 96h for resolved alarms | |||||
Windows Network Share: | □ | □ | □ | ● | ● | □ |
Network File System (NFS): | ♦ | ♦ | ♦ | ● | ● | ♦ |
FTP: | ● | ● | ● | ● | ● | ● |
USB: | ● | ● | ● | ● | □ | ● |
SD card: | ● | ● | ● | □ | □ | ● |
SATA Drive: SSD | ♦ | □ | □ | □ | □ | □ |
Email export: | ||||||
Extensions (modules are ordered separately) | VT960ii | VT855 | VT825 | NetBotz 750 | NetBotz 250 | VT335 |
Extensions: | CAN extension unit | CAN extension unit | CAN extension unit | Rack sensor pod, Room sensor pod | Rack Sensor Pod | CAN extension unit |
4G LTE modem: | ● | ● | ● | □ | □ | ● |
2G GSM modem: | ● | ● | ● | □ | □ | ● |
Wireless gateway: | ♦ | ♦ | ♦ | Zigbee | Zigbee | ♦ |
Built-in sensors | VT960ii | VT855 | VT825 | NetBotz 750 | NetBotz 250 | VT335 |
Temperature sensor: | ● | ● | ● | □ | □ | ● |
Power supply voltage sensor: | ● | ● | ● | □ | □ | ● |
Environmental characteristics | VT960ii | VT855 | VT825 | NetBotz 750 | NetBotz 250 | VT335 |
Operating temperature: | -10 to 80 °C | -10 to 80 °C | -10 to 80 °C | 0 - 40°C | 0 - 45°C | -10 to 80 °C |
Storage temperature: –25 to 85 °C | ● | ● | ● | -15 to 65 °C | -15 to 65 °C | ● |
Operating humidity: 0 to 90 %, non-condensing | ● | ● | ● | ● | ● | ● |
Storage humidity: 0 to 95 %, non-condensing | ● | ● | ● | ● | ● | ● |
Physical parameters | VT960ii | VT855 | VT825 | NetBotz 750 | NetBotz 250 | VT335 |
Installation: | 19”, 1U | 19”, 1U | 19”, 1U | 19”, 1U | 19”, 1U | Desktop |
Net dimensions (W x D x H): | 440*44*120mm | 440*44*90mm | 440*44*90mm | 432x178x43mm | 432*59*44mm | 180*35*80 |
Net Weight: | 2,2 kg | 1,5 kg | 1,5 kg | 2.45kg | 1.27kg | 0,7 kg |
Color: | Black | Black | Black | Black | Black | Black |
Case: | Sheet metal | Sheet metal | Sheet metal | Sheet metal | Sheet metal | Sheet metal |
Chassis grounding: M4 thread | ● | ● | ● | ● | ||
Conformance | VT960ii | VT855 | VT825 | NetBotz 750 | NetBotz 250 | VT335 |
Warranty: | 2 Years | 2 Years | 2 Years | 2 Years | 2 Years | 2 Years |
RoHS: | Compliant | Compliant | Compliant | Compliant | Compliant | Compliant |
REACH: | Compliant | Compliant | Compliant | Compliant | Contains SVHCs | Compliant |
Battery directive: | Compliant | Compliant | Compliant | Compliant | Compliant | Compliant |
Other features | VT960ii | VT855 | VT825 | NetBotz 750 | NetBotz 250 | VT335 |
GNSS on modems: | ● | ● | ● | □ | □ | ● |
Send SMS via another device: | ● | ● | ● | □ | □ | ● |
Macros: | ● | ● | ● | ● |
● Built-in □ None ● Extension ○ Not extendable