VT604t / Switched PDU with 4 Outlets is a versatile power distribution unit designed for effective load management in various environments. It enables users to switch on, off, or reboot up to eight individual outlets, providing flexible control over connected devices.
In addition to its power management capabilities, the VT604t also supports comprehensive environmental monitoring, including:
Temperature Monitoring: Keeps track of temperature levels to prevent overheating of equipment.
Humidity Monitoring: Ensures optimal humidity levels to protect sensitive devices.
Voltage Monitoring: Tracks voltage levels to safeguard against power surges or drops.
Leakage Detection: Monitors for water leaks to prevent damage to equipment.
Smoke Detection: Alerts users to potential fire hazards.
Airflow Monitoring: Ensures proper ventilation for cooling systems.
Furthermore, the VT608t functions as an I/O controller, making it suitable for various applications such as:
Door Control: Manage access points securely.
Fan Control: Regulate cooling systems to enhance equipment performance.
Generator Control: Manage backup power sources effectively.
UPS Management: Monitor and control uninterruptible power supplies.
Circuit Breaker Control: Automate circuit management for safety and efficiency.
Alarm Systems: Integrate alarms for enhanced security.
With the ability to manage up to 700 elements—including notifications, triggers, timers, logic schemes, sensors, and dry contacts—the VT604t offers robust functionality for complex setups. It features a built-in web interface, allowing users to create virtual sensors, implement logic schemes, and set up various types of notifications and control panels easily.
Supports a full range of Vutlan analog sensors and CAN devices/sensors. Supports Modbus TCP/IP.
Possible extensions:
VT485m / Modbus RTU extension or VT485r / OSPDv2 reader extension
VT-ACCU / Rechargeable reservation battery or VT-BAT / Reservation battery 6F22 9V
Notifications include E-mail, FTP log, Syslog, SMTP, SNMP Traps, Web-to-SMS, and PUSH.
Protocols include DHCP; HTTP; HTTPS; DynDNS; SSL; SNMP v1, v2c, v3; SMTP; FTP; Syslog; RADIUS; Modbus RTU; OpenVPN.
Virtual sensors include PING, timers, triggers, Logic schemes, SNMP GET, x4 IP cameras, Virtual math elements, and others.
Use cases
The VT604t / Switched PDU with 4 Outlets is designed for a variety of use cases, making it an essential tool in environments that require reliable power management and environmental monitoring. Here are some of its key applications:
Data Center Management: The VT604t allows data center operators to manage power to servers and networking equipment efficiently. By switching outlets on and off remotely, technicians can perform remote reboots and ensure optimal load distribution, which is crucial for preventing overheating and ensuring uptime.
Environmental Monitoring: This device enables the monitoring of critical environmental parameters such as temperature, humidity, voltage, and smoke. In data centers or server rooms, maintaining specific conditions is vital to prevent equipment damage. For instance, a spike in temperature detected by the VT608t can trigger alarms or automatic fan activation to cool down the equipment.
Control of Peripheral Equipment: The VT604t can be used to control peripheral devices such as fans, generators, and UPS systems. This functionality is especially useful during power outages, where the system can automatically switch to backup power while also managing other connected devices to maintain operations.
Security Systems: With its ability to control doors and alarms, the VT604t serves as a part of an integrated security system. It can manage access control systems and monitor for unauthorized access, ensuring that sensitive areas remain secure.
Customizable Logic Schemes: Users can set up complex logic schemes to automate responses based on specific conditions. For instance, if the humidity exceeds a set threshold, the system can automatically activate dehumidifiers or fans.
Energy Management: By monitoring voltage and power usage across multiple devices, the VT608t helps organizations optimize energy consumption and reduce costs. Alerts can be configured to notify operators of unusual power draw patterns that might indicate malfunctioning equipment.
Remote Monitoring and Management: The built-in web interface allows for easy remote access, enabling IT staff to monitor and control systems from anywhere. This capability is essential for businesses that operate multiple facilities or have off-site management needs.
These use cases illustrate the versatility and importance of the VT608t in modern IT and facility management, helping organizations maintain operational efficiency, safety, and reliability. For more detailed information, you can check the Vutlan product page directly.
Physical Description
Front panel:
Back panel:
1. "1U 19-inch brackets" - x2 pcs for mounting brackets into a 1U 19" rack slot.
2. "Analog sensors: A1..A8" - 8 RJ12 analog sensor inputs with auto-sensing. Read instructions at "Analog sensors connection", and "Sensor configuration".
3. "LAN port" - Ethernet 10/100 Base-T port, provides an Ethernet connection. Read more in this section "LAN, GSM, LTE, RADIUS, DNS, SSL, VPN".
"Orange LED" - orange LED for Ethernet port. It shows network traffic.
"Green LED" - green LED for Ethernet port. It shows network traffic. Flashes green when the system starts up. Shows the connection state (constant green light - the connection is established, blinking green - the connection attempt).
4. “USB” - A Micro USB port is needed for USB camera recording, USB Flash for system logs, and system restoration. Read instructions in "Connecting USB camera", "USB camera settings. How to save a video", "Saving system logs on USB flash drive", and "USB upgrade or restore of default settings".
5. "Modem slot" - "VT740 / LTE slot modem" can be installed in this slot. This modem is ordered separately. Read instructions at "VT740 / LTE slot modem", and "LAN, GSM, LTE, RADIUS, DNS, SSL, VPN".
6. "Sticker space" - A place for a sticker, can be used by a user to place an identifier of the system (for example, an IP address).
7. "Restart" - the button restarts the appliance. Hold the button for 2 seconds and then let go, and the system will restart.
8.1 "Activity" - green LED indicates appliance system status,
operating mode of the device: switches at a frequency of 2 times per second;
successful completion of the software update process: switches at a frequency of 4 times per second;
8.2 "Error" - red LED indicates error and traffic.
the operating mode of the device: If everything is normal, the LED is extinguished, if not - there's a constant glow;
software update mode: switches at a rate of 2 times per second;
8.3 "Alarm" - The LED can be programmed from the interface for alarm indication.
9. "TEMPERATURE SENSOR" - accuracy +/- 1 °C.
10.1 "CAN" - green LED indicates CAN bus status.
The LED blinks slowly - nothing is connected
The LED blinks fast - configuration is in process
The LED glows constantly - connected to CAN devices
10.2 "R1, R2, R3, R4" - LED status indicators for status of x4 C13 outlets.
The LED is ON (orange) - the relay is ON (the initial state can be configured).
The LED is OFF (LED is off) - the output is OFF (the initial state can be configured).
10.3 "E1, E2" - LED status indicators for 12V 0.25A Relay Outputs.
The LED is ON (orange) - the output is ON (the initial state can be configured).
The LED is OFF (LED is off) - the output is OFF (the initial state can be configured).
"OUTLETS 1-4" - x4 C13 outlets 110-240V AC, 50/60 Hz. Read more at Relay switching (NC NO) / Outlets switching.
“INLET” - C14 inlet, 110-240V AC, 50/60Hz, Fuse 10A 5x20mm
13. "Chassis grounding" - Chassis grounding, M4 thread. Enhances the immunity of the equipment against conducted and radiated RF disturbances. Please contact a professional electrician before connecting it.
14. “Battery Extension Slot” - Extension slot for “VT-ACCU / Rechargeable reservation battery” or “VT-6F22 / Reservation battery 9V”. Only one extension can be installed into this slot. Each extension is purchased separately.
15. "DC 12V BACKUP POWER" - This is a backup power terminal.
16. "Factory reset" - reset settings to default factory settings. Keep pressing the button for more than 5 seconds. The “Error” LED will start blinking. This indicates that the factory restoration has started. Wait for 20-60 seconds for the system to restart. The “Activity” LED will start blinking once the system has been restarted. The device can be accessed now.
17. "OUTPUTS 12V 0.25A" - 12V 0.25A (for each output) terminals outputs (electronic relay). LED indicators are located on the front panel. Read the instructions at "Connecting 12V devices to 12V outputs".
18. "DRY CONTACT INPUTS 1...2" - Digital inputs (Type IN). Read the instructions at "Connecting dry contacts", and "Dry contacts settings".
19. "CAN 1 / CAN 0" - Two digital connectors RJ12 for the connection of CAN sensors/extensions/devices on a CAN bus. Modules connected to these connectors can be chained together. Read the instructions at "CAN devises connection", and "Setting up CAN".
20. "SD card" - MicroSD card slot with an ejector. The card is needed for data storage or the "system restore". Read instructions at "Saving system logs to SD card", and "Restore of the appliance (for VT960 series)".
21. “Extension slot” - Only one of the two extensions can be installed “VT485m / Modbus RTU extension” or “VT485r / OSDP v2 reader extension”. Ordered separately.
19. “N - R" - DIP switch is used for different system modes.
Normal mode: The switch is switched to the left ←. The switch should be always in this position.
Restore of appliance: The switch is switched to the right →. Used to load the clean system image from an SD card. Read the instructions at “Restore of appliance”.
Connection overview diagram
Drawing dimensions
19” 1U installation in a rack-cabinet
1.1 | x2 19” brackets should be located in the package together with the system. Use x3 M3 screws to mount the brackets on each side of the unit. | |
1.2 |
| |
2 |
| Use x4 captive nuts and x4 M6 Screws to attached the unit to the rack. |
Installing VT485m / RTU modem extension slot
VT855t has a slot for an extension. You can install only one module in this slot. You can install the “VT485m / Modbus RTU modem extension slot” or the “VT485r / OSDPv2 reader extension slot”. Both modules are ordered separately.
Installing LTE slot modem
VT855t has a slot for “VT740 / LTE slot modem”. The modem is ordered separately.
Extension | Photo |
---|---|
|
Installing reservation battery
The unit has an “Extension battery slot” at the back of the unit. You can install VT-BAT / Reservation battery 6F22 9V or VT-ACCU / Rechargeable reservation battery.
Package content
Make sure that the contents of the delivery meet the following configuration. Report a missing or damaged component to your supplier. If damage occurred during transportation, contact the appropriate delivery service.
Package content | Description | Quantity | |
---|---|---|---|
1 | Switchable PDU unit VT604t. | x1 | |
2 | EU Schuko C13 0.75 мм2 230V 10A cable. | x1 | |
3 | RJ-45 3m patch cable | x1 | |
4 | USB adapter cable | x1 | |
5 | Terminal plug 3 pins, 3.81 mm | x1 | |
6 | Terminal plug 3 pins, 3.5 mm | x1 | |
7 | 19" rack brackets | x2 | |
8 | M3 x 8mm Phillips flat-head screws (transparent plastic bag 42x70mm) | x6 | |
9 | Self-adhesive rubber foot | x4 | |
10 | Configuration manual | x1 | |
11 | Warranty card | x1 |
Technical details
See a comparison table with technical details for each Vutlan PDU and monitoring unit at:
Frequently asked questions
Problem | Cause | Solution |
---|
Problem | Cause | Solution |
---|---|---|
The unit is not powering up. | The DIP switch is switched to the “R” position. | Switch the DIP switch to “N” position (Normal). |
|
|
|