Function and purpose

Product page: https://www.vutlan.com/accessories/40-vt105-strobe.html

Documentation link: https://vutlan.atlassian.net/wiki/spaces/DEN/pages/1834680385/VT103+Alarm+beacon


Needed for light and sound alarms. Has 1.5 m in length. Connects to 12V DC, 0.25A electronic relay of Vutlan monitoring systems.


Package includes

Package includes:

Package content

Description

Quantity

1

Alarm beacon with 1.5m cable

1 pc

2

4J-S sticky clamps

2 pcs

3

2.5mm Dowels

2 pcs

4

Screws for dowels, B2.9*20

2 pcs

Drawing


Installation drawing


Connecting 12V devices to Vutlan monitoring systems

All Vutlan monitoring systems and switched PDUs can connect up to two alarm beacons, for example, a siren and/or strobe, and other low-current devices, for example, a dry contact output module VT11, to E1, E2 - two outputs of electronic relays.

Connection

To connect the alarm beacon to the 12V output, you need to connect the device with a cable to the terminal according to the polarity. By appropriate logic or manually in the device interface, you can turn on or off and/or give a pulse to the siren, strobe, or a signal on a dry contact output. The maximum current consumption is limited by 250 mA.

Check the voltage supply in the test mode. Go to the Main Menu -> System Structure -> Alarm in the system interface. In the window that appears, click "Pulse". The stroboscope lights up, and the siren wails. To configure alarms, you need to configure the logic.

Do not connect the loads to the outputs while the monitoring system is on.

Further reading

12V relay configuration (alarm beacon or strobe light)

a) Login to the web interface of the monitoring system

b) To configure the relay: go to System tree >> Power 12V 0.25A >> Choose relay

c) By default Power-1 and Power-2. Rename it, set the initial state, and set Pulse duration time in seconds to a specific period.

Additionally: 12V relay configuration

12V relay configuration (for example, alarm beacon, strobe light, lock)

a) Login to the web interface of the monitoring system

b) To configure the relay: go to System tree >> Power 12V 0.25A >> Choose relay

c) By default Power-1 and Power-2. Rename it, set the initial state, and set Pulse duration time in seconds to a specific time period.

Connecting 12V devices to 12V outputs

Hardware configuration of 12V devices: Connecting 12V devices to 12V outputs

12V DC Vutlan devices

VT103 / Alarm beacon

VT105 / Strobe light

VT11 / Relay output

Cable pinouts

Strobe light uses a standard two-wire cable for connecting to the monitoring unit.

Technical specifications

VT105
DimensionsSize 70 x 36 x 56 mm, cable 3m
Weight
150g
Cable length3m
OutputLight and sound
Rated voltage12V DC, 1A
Power consumption250mA
Sound pressure108 dB
Tone frequency3.8 kHz
Flash frequency2.5Hz red 150/min
Mounting
Wall mount
HS code
8531 10 300
Case, colorABS plastic, red, white
IP rating standardIP54
Operating temperatureTemperature: Min. -50 °C - Max.105 °C
Operating humidityHumidity : Min. 5% - Max. 95% (Non-Condensing)
ComponentsManufactured in E.U.



Copyright of: