There is a simple possibility to return the factory default settings beginning from v. 2.5.1 and above.Image Removed

...

...

Legacy family units (VT200, VT800, VT1108, VT1808, VT1908, VT2100, VT8101, VT8110, VT8101T models):

On the reverse side of the running master, the unit turns the switch Normal / Recovery for 10-15 seconds to position Recovery. After the "Alarm" led will lightis lit, wait for a few seconds and return the switch Normal / Recovery to Normal position. LEDs flash, then off and the system will restart. You`ve got factory settings http://192.168.0.193, Login = guest, password = guest.

VT3xx, VT6xx, VT805, VT825 series models:

  1. The system has to be "On", and the "ACT" LED has to be active.

  2. At the backside of the unit, You should find a switch called "Normal / Recovery" (see picture above). Flip the switch to the "Recovery" position.

  3. After this, the red LED called "Error" will start to blink. While it blinks, flip the switch back to position "Normal". The "Error" LED may blink a few more times and after this, the system will restart for recovery settings to take effect. Both the "Alarm" and "ACT" LEDs will stop blinking.

    Info

    For the recovery process to take effect, you need to return the switch to "Normal" while the "Error" LED is blinking. If you wait too long while the "Error" LED is blinking, after around 20-30 seconds the "Error" LED will start to glow permanently. At this stage just flip the switch back to "Normal", no recovery will be done.

  4. After the system restarts, the "ACT" LED will start blinking again, which means that the system has been reset to factory settings and the system is operational.

  5. You`ve got factory settings http://192.168.0.193, Login = guest, password = guest.

Info

If the switch has been flipped to position "Recovery" by accident, do not flip it back. Wait until the "Error" LED stops blinking every second and starts to glow permanently. When the "Error" LED glows permanently, it is possible to flip the switch back to "Normal" without going into recovery mode, without losing any data.

VT335i, VT825i, and

...

VT855i series models:

      1. The system has to be "On", and the "ACT" LED has to be active.

      2. At the backside of the unit, You should find a button called "Reset Settings" (see picture below). Press and hold the button for a few seconds.

           

      3. After this, the red LED called "Error" will start to blink. While it blinks, release the button. The "Error" LED may blink a few more times and after this, the system will restart for recovery settings to take effect. Both "Alarm" and "ACT" LEDs will stop blinkinblinking.

      4. After the system restarts, the "ACT" LED will start blinking again, which means that the system has been reset to factory settings and the system is operational.

      5. You`ve got factory settings http://192.168.0.101, Login = guest, password = guest.