Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

General parameters

Description

Type:

Analog sensor, Plug&Play

Usage:

For Air quality and pollution monitoring.

Technology:

Laser scattering based on contamination-resistance technology with optical particle counters (OPCs)

Daisy chain connection:

Not possible

Sensor parameters

Mass concentration precision:

±10 %

Mass concentration range:

0 - 1000 μg/m³

Lifetime:

more than 10 years

Particle size range:

0.3 to 10.5 μm

Hardware parameters

Description/value

Best used in temperatures:

from +10° С to +40°C

Best used in humidity:

from 20% RH to 80% RH

Operating Temperature:

-10 to +60°C

Storage temperature:

-40 to +70°C

Operating humidity:

0 to 95% RH

Power Consumption:

Max. 400 mW in operation mode,

Installation

Cable length:

2 m

Mounting possibilities:

Wall or ceiling mount

Output terminal:

x1 RJ-11, 6p4c

Max. distance from the unit:

5GTIN:0 50 meters from Vutlan controller or from “VT408 / extension unit” or from “VT408DIN / DIN extension unit

Other

Manufactured in (country):

Manufactured in Slovak Republic, E.U.

Certification standards:

MCERTS-certified

HS Code:

9027102000

GTIN:

8588009886655

...