The PCB has no LEDs.

Installation

#

 

 

#

 

 

1

a) Unscrew x2 countersink screws at the panel named “Battery extension slot” located at the back of the monitoring system case.

b) take the panel out.

2

Insert the battery inside VT-ACCU PCB unit. 6F22 9V

Note

DO NOT USE RECHARGEABLE BATTERY! Only use Non-rechargeable battery!

Note

You can use 9V battery enclosed in standard PP3 enclosure

  • 6F22 (zinc-carbon batteries 400 mAh)

  • 6LR61 (alkaline batteries 565 mAh)

3

Push in the battery case with it’s legs into the PCB gaps.

4

Slide the battery case so that it locks into the PCB.

5

Screw the unit to the panel that we have unscrewed in step one using x2 screws M3.

6

a) Plug the assembly into the monitoring system slot named “Batttery extenion slot”.

b) Screw the panel to the enclosure using x2 countersink screws that we have received in step 1.