VT335iVT335x, VT336VT336x, VT825iVT825x, VT825ii, VT855i, VT855ii, VT960i, and VT960ii VT855x, VT960x are the monitoring units and can not connect to each other. For scalability please use extension units and embedded boards.
...
● Built-in □ None ♦ Extension possible ◊ Not extendable
VT960 |
---|
VT825t
Device Management: Web, SNMP |
Yes | Yes | Yes | Yes | Yes | Yes |
Yes
Yes
Yes
Sensor access: Three-level by login | Yes | Yes | Yes | Yes | Yes | Yes |
Interface |
VT960 |
Interface
VT325t
VT335t
VT825t
LAN: Ethernet 10/100 Mbit |
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
2 x 1 Gbit | 100 Mbit | 100 Mbit | 100 Mbit | 100 Mbit | 100 Mbit |
OS: Linux | v. |
v.5.40
v.5.40
v.5.40
v.3.10
6.2 | v.6.2 | v.6.2 | v.6.2 | v.6.2 |
Interface: Any browser |
Yes
Yes
Yes | Yes | Yes | Yes | Yes | Yes | |
Memory RAM: |
2 Gb | 128 Mb | 128 |
64
Mb |
64 Mb
128 Mb
128 Mb | 128 Mb | 128 Mb |
CPU speed: |
720 MHz
600 MHz
600 MHz
600 MHz
1.8 GHz | 1 GHz | 720 MHz | 720 MHz | 720 MHz | 600 MHz |
720 MHz
720 MHz
720 MHz
Total CPU cores: |
4
1
1
1
8 | 2 | 2 | 2 | 2 | 2 |
Clock: Built-in clock |
Yes | Yes | Yes | Yes | Yes | Yes |
Yes
Yes
Timer: Built-in watchdog |
Yes
Yes
Yes | Yes | Yes | Yes | Yes | Yes | |
The maximum amount of sensors: physical sensors, dry contacts, relays |
500 | 150 |
130 | 100 |
30
150
150
150
100 | 100 |
The maximum amount of elements: notifications, triggers, timers, logic, sensors, dry contacts, SNMP Get, SNMP Trap, Dial task, and other elements |
3000 | 1000 | 1000 | 700 |
700 |
1000
1000
1000
1000
700 | ||||||
Networking / Protocol support |
VT960 |
VT825t
LTE Gateway mode: Internet access (routing for internal network) (modem ordered separately) | Yes | Yes | Yes | Yes |
No
Yes |
Yes
Yes
- | |||||
LTE Access mode: Internet access over LTE (modem ordered separately) | Yes | Yes | Yes | Yes | Yes |
Yes
Yes
Yes
Yes
- |
Network protocols: DHCP; HTTP; HTTPS; SNMP v1, v2c, v3; SMTP; FTP; Syslog; TLS; |
Yes
Yes
Yes | Yes | Yes | Yes | Yes | Yes | |
Modbus RTU |
Yes
Yes
No
No
Yes
No
VT485m extension (Modbus or Reader)
VT485m extension (Modbus or Reader)
Using extension VT485m | Using extension VT485m | Using extension VT485m | Using extension VT485m | Using extension VT485m | - |
RS485 / OSDPv2: reader access control |
Modbus TCP / IP
Yes
Yes |
No
No
No
No
No
VT485r extension (Modbus or Reader)
VT485r extension (Modbus or Reader)
VT485r extension (Modbus or Reader)
Using extension VT485R | Using extension VT485R | Using extension VT485R | Using extension VT485R | - | |
Modbus TCP / IP | Yes | Yes | Yes | Yes | Yes |
Yes |
Yes
Yes
Static routing |
Yes
Yes | Yes | Yes | Yes | Yes | Yes | |
Dynamic DynDNS |
Yes
Yes
Yes | Yes | Yes | Yes | Yes | Yes | |
Access via RADIUS server | Yes | Yes | Yes | Yes | Yes | Yes |
Yes
Yes
Yes
VPN: secure data communications; secure change of connection between LTE and LAN | Yes | Yes | Yes | Yes | Yes |
No
Yes
Yes
- |
SSL installation |
Yes | Yes | Yes | Yes | Yes | Yes |
Yes
Yes
NTP server | Yes | Yes | Yes | Yes | Yes | Yes |
Yes
Yes
Yes
Alerts / Notifications |
VT325t
VT335t
VT825t
VT960 | |||||
Alert types: E-mail, FTP log, Syslog, SMTP, SNMP Traps, SMS (Modem is ordered separately), Web-to-SMS, |
Yes
Yes
Yes | Yes | Yes | Yes | Yes | Yes | |
A maximum number of "mail to" recipients in an E-mail notification: |
50
20 | 20 | 20 |
20 | 20 | 20 |
20
A maximum number of "SMS to" recipients in an SMS notification: also the maximum amount of phone numbers |
20 | 20 | 20 |
20 | 20 |
20
- | ||||||
Virtual sensors |
VT325t
VT335t
VT825t
VT960 | |||||
Pings: Built-in function for server pinging. Test the reachability of a host in a network. |
Yes
Yes
Yes | Yes | Yes | Yes | Yes | Yes | |
IP cameras: Connect the IP MJPEG camera with a proxy via the master module. Only view, no record. |
4 | 4 | 4 | 4 | 4 | 4 |
4
4
Get SNMP: Read data from external equipment via SNMP PDU GET (v1/2c) |
Yes
Yes
Yes | Yes | Yes | Yes | Yes | Yes | |
User keys: Add users who have access using an RFID reader. | Yes | Yes | Yes |
Yes |
Yes |
Yes
- |
Logic schemes: Used to specify automatic actions to events that occur in the system. |
Yes
Yes
Yes | Yes | Yes | Yes | Yes | Yes | |
Timers: Allows you to plan the events in the system. |
Yes
Yes
Yes | Yes | Yes | Yes | Yes | Yes | |
Triggers: Generate events in the system if logic is triggered. | Yes | Yes | Yes | Yes | Yes | Yes |
Yes
Yes
Yes
SNMP traps | Yes | Yes | Yes | Yes | Yes | Yes |
Yes
Yes
Yes
Virtual Math element (combine several sensor data and calculate new data) | Yes | Yes | Yes | Yes | Yes | Yes |
Yes
Yes
Yes
Logic schemes |
Yes
Yes
Yes | Yes | Yes | Yes | Yes | Yes | |
Modbus TCP/IP: read/write |
Yes | Yes | Yes | Yes |
Yes | Yes |
Yes
Power |
VT960 |
VT825t
VT855t
Power input (230V AC):
Energy efficiency: (EU Energy level) | Grad C | Grad A | Grad A | Grad A | Grad A | Grad A |
Power input (230V AC): | x2 inputs option | x2 inputs option | x2 inputs option |
- |
No
No
No
x2 inputs option
x2 inputs option
- | - |
Power input (24 ÷ 48V DC): | x2 inputs |
option | x2 inputs option | x2 inputs option |
Yes |
- |
No
No
x2 inputs option
x2 inputs option
- |
Power input (12V DC): |
- | x1 input option | x1 input option | x2 inputs |
Input | Input |
x2 inputs
x1 input option
Fuse: Fuse at the inlet | 1 A | 1 A | 1 A | PTC |
PTC |
□
No
No
1 A
1 A
PTC | ||||||
Min. power consumption: | 5 W | 1 W | 1 W | 1 W | 1 W | 1 W |
Max. power consumption: |
25 W |
10 W | 10 W | 10 W |
12 W
10 W | 6 W |
10 W
30 W
The maximum current load on the relay: | 10А | 10А | 10А | 250mА | 250mА | 250mА |
250mА
10А
10А
Redundant power supply: built-in voltage monitor, voltage range 9-12.6V. | Yes AC/DC DC/DC | Yes AC/DC DC/DC | Yes AC/DC DC/DC | Yes |
DC 12V
□
Yes
AC/AC, AC/DC,DC/DC | Yes |
DC 12V | - | |||||
Outputs |
VT325t
VT335t
VT825t
VT855t
VT960 | |||||
Relay outputs: latching relays 240V*10A | 2 | 2 | 2 |
- |
□
□
□
2
2
- | - |
Relays outputs: 12V 0.25A |
2
2
2 | 2 | 2 | 2 | 2 | 2 | |
Max. dry contact outputs (contact closures/digital outputs) |
2 | 8 |
- |
5 |
□
□
□
□
- | - | |||||
Inputs |
VT960 |
VT825t
Analog port: 6P6C for connection of an analog sensor. (extendable using CAN bus) | 8 built-in ports, |
extended using extension unit | 8 built-in ports, |
extended using extension unit | 8 built-in ports, |
extended using extension unit | 4 built-in ports, |
extended using extension unit |
4 built-in ports, |
extended using extension unit | 4 built-in ports, |
4 built-in ports,
up to 16 on the CAN bus extension unit
8 built-in ports,
up to 16 on the CAN bus extension unit
8 built-in ports,
up to 16 on the CAN bus extension unit
extended using extension unit |
CAN port: Max number of sensors Use CAN-12V-1A for connecting more than 12 devices. |
x2 port, |
x32 devices in total |
x2 port, |
x32 devices in total | x1 port, max. 32 devices | x1 port, max. |
32 devices | x1 port, max. 32 devices | x1 port, max. |
10 devices |
Dry contact inputs: (contact closures/digital inputs) |
Extadable using CAN bus and Dry contacts unit
48 | 32 | 16 |
8 | 4 | 2 |
4
32
Video
VT325t
VT335t
VT825t
VT855t
Video cameras:
AV, x2 USB, x4 IP
USB, x1 IP
USB, x1 IP
USB, x1 IP
USB, x1 IP
USB, x1 IP
USB, x1 IP
USB, x1 IP
USB, x1 IP
Other connectors
VT325t
VT335t
VT825t
VT855t
Ethernet port: 10/100Mbit
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Modbus RTU (RS-485): Max. line length 1000m |
1 built-in port, up to 50 sensors
1 built-in port, up to 50 sensors
□
□
1 built-in port, up to 50 sensors
□
Extension
□
VT485m extension (Modbus or Reader), up to 50 sensors
Using extension VT485m | Using extension VT485m | Using extension VT485m | Using extension VT485m | Using extension VT485m | - | |
OSDP v2 reader extension: | Yes | Using extension VT485R | Using extension VT485R | Using extension VT485R | Using extension VT485R | - |
Video | VT960 | |||||
USB cameras | 1 | 1 | 1 | 1 | 1 | 1 |
IP cameras | x4 | x4 | x4 | x4 | x4 | x4 |
RTSP IP camera | 2 | - | - | - | - | - |
Other connectors | VT960 | |||||
Ethernet port: 10/100Mbit | - | 1 | 1 | 1 | 1 | 1 |
Ethernet port: 10/100/1000Mit | 2 | - | - | - | - | - |
USB 2.0 Type A |
2 |
- |
- |
- |
□
□
□
1
- | - |
USB 2.0 |
1
Type C | 1 | 1 | 1 | 1 | 1 | 1 |
1
Switch Normal / Recovery: returns the device to factory |
□
Yes
settings | Yes | Yes | Yes | Yes | Yes | Yes |
External Memory / Logs |
VT960 |
VT825t
Micro SD memory card slot (SDXC up to |
Yes
512 Gb) | Yes | Yes |
Yes | Yes | Yes | Yes | |
SD card formatting function (FAT32) | Yes | Yes | Yes | Yes |
No
Yes
Yes | Yes |
Yes
USB flash drive: logs, sensor readings, item settings, etc. |
Yes
Yes
Yes | Yes | Yes | Yes | Yes | Yes | |
Send system log to e-mail: Logs, sensor data, elements settings, etc. |
Yes
Yes | Yes | Yes | Yes | Yes | Yes |
Yes
Sensor dump files: save the per-second samples of analog and discrete |
Yes
Yes
sensors | Yes | Yes | Yes | Yes | Yes | Yes |
Yes
Yes | Yes | Yes | Yes | Yes | Yes |
Yes
Send to FTP server: Logs, sensor data, elements settings, etc. |
Yes
Yes
Yes | Yes | Yes | Yes | Yes | Yes | |
Maximum amount of log files: 10,000 logs/days = 27 years |
Yes
Yes
Yes | Yes | Yes | Yes | Yes | Yes | |
Sample rate/period (logs, graphs) | 1 s | 1 s | 1 s | 1 s | 1 |
1 s
1 s
1 s
s | 1 s | |||||
Reservation of settings | VT960 | |||||
“i” series (e.g. VT335i): System settings are compatible | Yes | Yes | Yes | Yes | Yes | |
Modem (extension ordered separately) |
VT960 |
VT825t
4G LTE modem: ordered separately. |
VT7672 |
- |
Modem modes:
|
Gateway / Access / SMS
| Gateway / Access / SMS | Gateway / Access / SMS | Gateway / Access / SMS | Gateway / Access / SMS | Gateway / Access / SMS | - |
Modem LED: STATUS | Yes | Yes | Yes | Yes | Yes |
Yes
Yes
Yes
Yes
- | ||||||
Embedded onboard sensors |
VT960 |
VT825t
Temperature sensor: +/- 1 °C PCB temperature. | Yes | Yes | Yes | Yes | Yes | Yes |
Yes
Yes
Yes
Power supply voltage sensor: Accuracy (1%) |
1
Main & Reserve | Main & Reserve | Main & Reserve |
1
Yes
Main & Reserve | Main & Reserve | Yes | ||||
LED |
VT325t
VT335t
VT825t
indication | VT960 | |||||
Ethernet LAN: LINK |
Yes | Yes | Yes | Yes | Yes | Yes | |
Ethernet LAN: ACT |
Yes | Yes | Yes | Yes | Yes | Yes | |
CAN bus: STATUS | Yes | Yes | Yes | Yes | Yes | Yes |
Yes
System: STATUS (ACT) |
Yes | Yes | Yes | Yes | Yes | Yes | |
System: ERROR (ERR) | Yes | Yes | Yes | Yes | Yes | Yes |
Yes
System: ALARM |
Yes | Yes | Yes |
Yes | Yes | Yes | |
12V 0.25A outputs: STATUS (e.g. E1, E2) |
x2 | x2 | x2 | x2 | x2 | x2 | |
MODBUS |
-
-
-
-
x1
-
-
TX: Modbus data sent activity (Transmission).
Yes
Yes
-
-
-
-
Yes
RTU: STATUS | VT485M | VT485M | VT485M | VT485M | VT485M | - |
ODSP Reader. | Yes |
VT485R |
VT485R |
VT485R |
VT485R | - |
Yes
NC/NO/COM Relay (e.g. R1, R2) |
x2
x2
x2
-
x2 | x2 |
HDD: Hard drive STATUS
Yes
-
-
x2 | - | - | - | |||
Environmental characteristics |
VT960 |
VT825t
Operating temperature: -10 to |
70 °C |
Yes | Yes | Yes | Yes | Yes | Yes | |
Storage temperature: –25 to 85 °C |
Yes | Yes | Yes | Yes | Yes | Yes | |
Operating humidity: 0 to 90 %, non-condensing |
Yes | Yes | Yes | Yes | Yes | Yes | |
Storage humidity: 0 to 95 %, non-condensing |
Yes | Yes | Yes | Yes | Yes | Yes | |
Other Features |
VT325t
VT335t
VT825t
VT960 | ||||||
Installation: | 19” 1U | 19” 1U | 19” 1U | DIN rail, Wall | Desktop | Desktop |
DIN rail
19” 1U
Casing: | Sheet metal | Sheet metal | Plastic | Sheet metal | Plastic | |
Dimensions (L x W x H) in mm: |
440*44*120
440*44*90
440*44*90
180*35*80
160*90*58
440*44*90
440x44x90 | 440x44x90 | L_212.5 H_90.1 D_32.20 | 180x35x80 | 150x29x100 |
Weight: |
2 kg
1, |
6 kg | 1,5 kg | 0,7 kg | 0 |
1,5 kg
,5 kg | ||||
External chassis grounding: M4 thread | Yes | Yes | Yes | Yes |
Yes | Yes | |||||
Web interface (panels) |
VT325t
VT335t
VT825t
VT960 | |||||
Dashboard panel: |
Yes | Yes | Yes | Yes | Yes | Yes | |
Overall statistics panel: |
Yes | Yes | Yes | Yes | Yes | Yes | |
System tree panel: sensors and devices displayed in a hierarchy |
Yes
Yes | Yes | Yes | Yes | Yes | Yes | |
Dry outputs panel: | Yes | Yes | Yes |
No
Yes |
No | Yes | |||||
Dry inputs panel: | Yes | Yes | Yes | Yes | Yes | Yes |
Yes
Event log panel: amount of logs |
Yes | 300 | 300 | Yes | 300 | 200 |
300
Logic schemes panel: | Yes | Yes | Yes | Yes | Yes | Yes |
Yes
Cameras panel: |
Yes | Yes | Yes | Yes | Yes | Yes | |
Map panel: 5 layers | Yes | Yes | Yes | Yes | Yes | Yes |
Yes
Users panel: |
Yes | Yes | Yes | Yes | Yes | Yes | |
CAN configuration panel: |
Yes | Yes | Yes | Yes | Yes | Yes | |
Graphs panel: |
Yes | Yes | Yes | Yes | Yes | Yes | |
Reset smoke detectors panel: |
Yes | Yes | Yes | Yes | Yes | Yes | |
Preferences panel: Web GUI, Network, Time, Logging, DynDNS, SNMP, RADIUS, FTP backup, VPN Clent, Modbus RTU, GPS, SMTP, Routing | Yes | Yes | Yes | Yes | Yes | Yes |
System menu panel: About, Firmware, Export, Support |
Yes | Yes | Yes | Yes | Yes | Yes | |
List of latest sent SMS messages: | 200 |
200 | 200 | 200 | 150 |
200 |
200
Analog sensor power reset: resets smoke sensors |
Yes | Yes | Yes | Yes | Yes | Yes |
● Built-in □ None ♦ Extension possible ◊ Not extendable