Function and purpose
For installation inside of IT racks and cabinets. Sensor controls status of door or window: open, closed.
Safety Instructions
- Regularly check that the IR sensor is not covered with dust.
- Do not expose the IR sensor to direct sunlight.
- Make sure that you do not scratch the IR sensor during installation and operation.
Package includes
The optical access sensor consists of:
- Converter inside of a compact plastic housing
- IR sensor
- Bracket for mounting of both the converter and the IR sensor
- Bolts, screws and nuts
- RJ11 two meter cable
- Sticker
Connecting optical access sensor
...
Table of Contents | ||
---|---|---|
|
Documentation page: https://vutlan.atlassian.net/wiki/spaces/DEN/pages/1711833089/VT530+Access+sensor
Product page: https://vutlan.com/analog-sensors/18-vt530-access-sensor.html
Function and purpose
The VT530 Access Sensor is essential for access control and is designed to monitor the status of doors and windows (open or closed). It consists of two parts: a magnet and a sensor, ensuring accurate detection of access points being opened or closed. It can be connected to any analog port (A1...A8)
...
of
...
Adjusting sensor sensetivity and LED indication
Adjusting sensetivity
Use flat-head screwdriver to adjust the sensor sensetivity.
Turning the screwdriver clock-wise will increase view distance up to 3 - 4 cm.
Turning the screwdriver counterclock-wise will decrease the view distance down to 1 cm.
Info |
---|
It is possible to decrease view distance of the sensor below 10mm, but only if the sticker is bend in a spherical shape. This is because IR sensor uses two beams which require some distance to work properly. |
LED indication
The sensor has red LED sticking out on top of the sensor. By default the sensor is configured to:
- If the door is closed, red light is Off.
- If the door is open, red light is On.
Installation inside a rack or cabinet using a bracket
Mounting bracket
Mounting bracket is supplied with each "VT531 / Optical access sensor".
Pic.1
Pic. 2
Bent
Pic. 3
Bent and cut
Installation
Bracket steel thickness is 0.8 mm. Below You can find how user can mount "VT531 / Optical access sensor" with such a bracket.
Example 1
Bracket is mounted to two captive nuts using two M6 bolts. Pliers used for fitting. VT531 plastic case is mounted onto the bracket using M4 bolts and M4 nuts. IR sensor is mounted using two M2x10 bolts and two M2 nuts. IR sensor is pointing towards the door.
Example 2
Bracket is mounted to the rack using two 4.8*13 screws. Pliers used for fitting. VT531 plastic case is mounted onto the bracket using M4 bolts and M4 nuts. IR sensor is mounted using two M2x10 bolts and two M2 nuts. IR sensor is pointing towards the door.
Example 3
Bracket is glued to the rack using a sticker. Pliers used for fitting. IR sensor is pointing towards the door. The door is opened in current case.
Cable pinouts
"RJ11/RJ12" to "RJ11/RJ12" cable pinouts:
RJ9 4p4c to IR sensor cable pinouts:
Technical specifications
...
the Vutlan monitoring unit and supports daisy chaining, allowing multiple sensors to be linked in a series for easy and scalable installations.
For larger systems, the number of sensors and overall cable length can be extended using the VT408 Sensor Extension Unit, allowing for scalable access control across multiple entry points.
This sensor is ideal for securing sensitive areas and ensuring continuous monitoring of entry status.
Info |
---|
The sensor can not be used on its own. It must be used together with Vutlan monitoring systems. |
Used for
The VT530 Access Sensor is primarily used for:
Access Control: It monitors the status of doors and windows (open or closed), making it ideal for securing entry points in sensitive areas like server rooms, data centers, and restricted facilities.
Intrusion Detection: It can detect unauthorized access attempts by monitoring the status of doors and windows, and alerting security systems when entry points are breached.
Automation Systems: Integrated into automation systems, it can trigger actions such as locking doors, activating alarms, or adjusting environmental controls when doors or windows are opened or closed.
Server Rack Access Control: It monitors whether server rack doors are open or closed, providing real-time status updates. This is critical for securing sensitive IT equipment and preventing unauthorized access to servers and networking hardware.
This sensor is crucial in environments where constant access monitoring is required for safety, security, or automation purposes.
Technical specifications
VT530 | |
---|---|
Type | Analog sensor |
Measures | Contact closed/open using a magnet |
Chainable | Yes. All sensors in a chain show as 1 element in web interface. Triggering any sensor triggers the same element. |
Dimensions | 600×18x18 mm |
Weight | 106 g |
Inputs |
RJ11 / RJ12 ( |
6p4c) | |
Outputs | RJ11 / RJ12 (6p4c) |
Operating temperature | Min. -10° C, Max.80° C |
Operating humidity | Min. 5% - Max. 95% (Non-Condensing) |
Mounting | Mounting bracket, bolts, and stickers included for installation inside IT racks and cabinets |
Power consumption | 60mW |
Max. distance m | 150 m |
Manufactured in | Slovak Republic, E.U. |
HS Code | 8531 10 300 |
...
GTIN | 8588009886167 |
Connecting the sensor
Connect one end of the RJ11(6p4c) cable to the monitoring unit into any analog ports (A1...A8) and the other end to the "VT530 / Access sensor".
The access sensor will appear automatically in a System tree.
...
Installation inside a rack or cabinet using a bracket
Mounting bracket
A mounting bracket is supplied with the unit.
...
Installation
Example 1
The magnet needs to be mounted on the door or the window. If the door is open, the switch is Open. If the door is closed, the switch is Closed. You can reverse the logic inside the Web UI interface.
Depending on the construction of the door/window/rack you can use supplied bolts, stickers, or a mounting bracket to mount the sensor and the magnet.
...
Cable pinouts
"RJ11/RJ12" to "RJ11/RJ12" cable pinouts:
...
Package content
Included page VT530 package content
Include Page | ||||
---|---|---|---|---|
|
Drawings
VT530 magnet:
...
VT530 sensor:
...
Sensor angle:
...
|
| |||||||||
|
|
Pages of interest
...
Copyright:
Vutlan s.r.o. (LLC)
Remote Infrastructure Monitoring and Control
43 ul.Svornosti, 821 06 Bratislava,
Slovak Republic