The sensor detects water by the drop in resistance of the WLC water detection leak cable. The sensor must be used together with :
...
the WLC leak cable. WLC leak cable is ordered separately, different lengths can be ordered.
VT591 can be connected to any analog port (A1...A8) of the Vutlan monitoring unit.
The maximum amount of VT591 sensors connected to a single monitoring unit and the maximum length from the monitoring or extension unit can be extended using the VT408 / Sensor extension unit.
"WLC / Water leak cable" is ordered separately! When water is in contact with the detection cable, a resistive sensor indicates the emergence of moisture. |
---|
...
The whole area can be effectively monitored by placing the cable near or with possible flood sources. |
---|
Order options
Info |
---|
If you need 18m WLC cable, you can connect together WLC3 + WLC15. |
...
VT591 / Water leak sensor specifications | |
---|---|
Sensor type: | Analog sensor |
Measures: | Detects water leakage by the drop in resistance in WLC water leak cable |
Chain connection | No |
Dimensions: | 60×18×18 mm |
Weight: | 60 g |
InputInputs: | 2 wire (WLC cable) |
Detection | Resistive |
OutputOutputs: | RJ11/RJ12 (6p4c) |
Operating temperature: | -10 °C to +80 °C |
Operating humidity: | 5% to 95% (Non-Condensing) |
Mounting: | Mounting bracket included. |
Power consumption: | 60mW |
Max. distance m: | 100 m |
HS Code | 9025 80 400 |
Components | Manufactured in E.U. |
Special features | from the monitoring or extension unit |
Response time: | 15 sec., |
Recovery time: | Depends on how fast the sensor dries out |
Manufactured in: | Slovak Republic, E.U. |
HS Code: | 9025 80 400 |
GTIN | 8588009886211 |
WLC / Water leak cable specifications | |
---|---|
Description | WLC can work in high humidity, pollution, and hazardous waste |
Detectable liquids | Clean, polluted & distilled water; acids; alkalis; alcohols, and other electrically conductive liquid |
Diameter | 6.5 mm in diameter |
Lengths | Order options include 3m, 6m, 10m, 15m, 25m, 50m, or custom length. |
Weight | 36 g/m |
Operating humidity | 0% - 95 % |
Max. storage temperature | 75°C |
Max. cable length | 100 m |
Inputs | x2 wires |
...