VT335t, VT336t, VT825t, VT825tt, VT855t, VT855tt, VT960t and VT960tt are the monitoring units and can not connect to each other. For scalability please use extension units and embedded boards.
...
Versions | ||||||||
---|---|---|---|---|---|---|---|---|
Device Management: Web, SNMP | Yes | Yes | Yes | Yes | Yes | Yes | ||
Sensor access: Three-level by login | Yes | Yes | Yes | Yes | Yes | Yes | ||
Interface | ||||||||
LAN: Ethernet 10/100 Mbit | Yes | Yes | Yes | Yes | Yes | Yes | ||
OS: Linux | v.5.10 | v.6.2 | v.6.2 | v.6.2 | v.6.2 | v.6.2 | ||
Interface: Any browser | Yes | Yes | Yes | Yes | Yes | Yes | ||
Memory RAM: | 1 Gb | 128 Mb | 128 Mb | 128 Mb | 128 Mb | 128 Mb | ||
CPU speed: | 720 MHz | 1 GHz | 720 MHz | 720 MHz | 720 MHz | 600 MHz | ||
Total CPU cores: | 4 | 2 | 2 | 2 | 2 | 2 | ||
Clock: Built-in clock | Yes | Yes | Yes | Yes | Yes | Yes | ||
Timer: Built-in watchdog | Yes | Yes | Yes | Yes | Yes | Yes | ||
The maximum amount of sensors: physical sensors, dry contacts, relays | 400 | 150 | 130 | 100 | 100 | 100 | ||
The maximum amount of elements: notifications, triggers, timers, logic, sensors, dry contacts, SNMP Get, SNMP Trap, Dial task, and other elements | 2000 | 1000 | 1000 | 700 | 700 | 700 | ||
Networking / Protocol support | ||||||||
LTE Gateway mode: Internet access (routing for internal network) (modem ordered separately) | Yes | Yes | Yes | Yes | Yes | No | ||
LTE Access mode: Internet access over LTE (modem ordered separately) | Yes | Yes | Yes | Yes | Yes | No | ||
Network protocols: DHCP; HTTP; HTTPS; SNMP v1, v2c, v3; SMTP; FTP; Syslog; TLS; | Yes | Yes | Yes | Yes | Yes | Yes | ||
Modbus RTU | Using extension VT485m | Using extension VT485m | Using extension VT485m | Using extension VT485m | Using extension VT485m | No | ||
RS485 / OSDPv2: reader access control | Yes | Yes | Yes | Yes | Yes | No | ||
Modbus TCP / IP | Yes | Yes | Yes | Yes | Yes | Yes | ||
Static routing | Yes | Yes | Yes | Yes | Yes | |||
Dynamic DynDNS | Yes | Yes | Yes | Yes | Yes | Yes | ||
Access via RADIUS server | Yes | Yes | Yes | Yes | Yes | Yes | ||
VPN: secure data communications; secure change of connection between LTE and LAN | Yes | Yes | Yes | Yes | Yes | No | ||
SSL installation | Yes | Yes | Yes | Yes | Yes | Yes | ||
NTP server | Yes | Yes | Yes | Yes | Yes | Yes | ||
Alerts / Notifications | ||||||||
Alert types: E-mail, FTP log, Syslog, SMTP, SNMP Traps, SMS (Modem is ordered separately), Web-to-SMS, | Yes | Yes | Yes | Yes | Yes | Yes | ||
A maximum number of "mail to" recipients in an E-mail notification: | 50 | 20 | 20 | 20 | 20 | 20 | ||
A maximum number of "SMS to" recipients in an SMS notification: also the maximum amount of phone numbers | 50 | 20 | 20 | 20 | 20 | |||
Virtual sensors | ||||||||
Pings: Built-in function for server pinging. Test the reachability of a host in a network. | Yes | Yes | Yes | Yes | Yes | Yes | ||
IP cameras: Connect the IP MJPEG camera with a proxy via the master module. Only view, no record. | 4 | 4 | 4 | 4 | 4 | 4 | ||
Get SNMP: Read data from external equipment via SNMP PDU GET (v1/2c) | Yes | Yes | Yes | Yes | Yes | Yes | ||
User keys: Add users who have access using an RFID reader. | Yes | Yes | Yes | Yes | Yes | No | ||
Logic schemes: Used to specify automatic actions to events that occur in the system. | Yes | Yes | Yes | Yes | Yes | Yes | ||
Timers: Allows you to plan the events in the system. | Yes | Yes | Yes | Yes | Yes | Yes | ||
Triggers: Generate events in the system if logic is triggered. | Yes | Yes | Yes | Yes | Yes | Yes | ||
SNMP traps | Yes | Yes | Yes | Yes | Yes | Yes | ||
Virtual Math element (combine several sensor data and calculate new data) | Yes | Yes | Yes | Yes | Yes | Yes | ||
Logic schemes | Yes | Yes | Yes | Yes | Yes | Yes | ||
Modbus TCP/IP: read/write | Yes | Yes | Yes | Yes | Yes | Yes | ||
Power | ||||||||
Power input (230V AC): | x2 inputs option | x2 inputs option | x2 inputs option | No | No | No | ||
Power input (24 ÷ 48V DC): | x2 inputs option | x2 inputs option | x2 inputs option | No | No | No | ||
Power input (12V DC): | No | x1 input option | x1 input option | x2 inputs | x2 inputs | Input | ||
Fuse: Fuse at the inlet | 1 A | 1 A | 1 A | PTC | PTC | PTC | ||
Min. power consumption: | 6W | 1 W | 1 W | 1 W | 1 W | 1 W | ||
Max. power consumption: | 30 W | 10 W | 10 W | 10 W | 10 W | 6 W | ||
The maximum current load on the relay: | 10А | 10А | 10А | 250mА | 250mА | 250mА | ||
Redundant power supply: built-in voltage monitor, voltage range 9-12.6V. | Yes AC/DC DC/DC | Yes AC/DC DC/DC | Yes AC/DC DC/DC | Yes DC/DC | Yes DC 12V | - | ||
Outputs | ||||||||
Relay outputs: latching relays 240V*10A | 2 | 2 | 2 | - | - | - | ||
Relays outputs: 12V 0.25A | 2 | 2 | 2 | 2 | 2 | 2 | ||
Max. dry contact outputs (contact closures/digital outputs) | 8 | 8 | - | 5 | - | - | ||
Inputs | ||||||||
Analog port: 6P6C for connection of an analog sensor. (extendable using CAN bus) | 8 built-in ports, extended using extension unit | 8 built-in ports, extended using extension unit | 8 built-in ports, extended using extension unit | 4 built-in ports, | 4 built-in ports, extended using extension unit | 4 built-in ports, extended using extension unit | ||
CAN port: Max number of sensors Use CAN-12V-1A for connecting more than 12 devices. | x1 port, max. 32 devices | x2 port, max. 362 devices | x1 port, max. 32 devices | x1 port, max. 32 devices | x1 port, max. 32 devices | x1 port, max. 10 devices | ||
Dry contact inputs: (contact closures/digital inputs) | 32 | 32 | 16 | 8 | 4 | 2 | ||
Modbus RTU (RS-485): Max. line length 1000m | Using extension VT485m | Using extension VT485m | Using extension VT485m | Using extension VT485m | Using extension VT485m- | - | ||
OSDP v2 reader extension: | Using extension VT485R | Using extension VT485R | Using extension VT485R | Using extension VT485R | Using extension VT485R | - | ||
Video | ||||||||
USB cameras | x2 | x1 | x1 | x1 | x1 | x1 | ||
IP cameras | x4 | x4 | x4 | x4 | x4 | x4 | ||
RTSP IP camera | x1 | - | - | - | - | - | ||
Other connectors | ||||||||
Ethernet port: 10/100Mbit x1 | x1 | x1 | x1 | x1 | x1 | x1 | ||
Ethernet port: 10/100/1000Mit | x1 | - | - | - | - | - | ||
USB 2.0 Type A | x1 | - | - | - | - | - | ||
USB 2.0 micro | x1 | x1 | x1 | x1 | x1 | x1 | ||
Switch Normal / Recovery: returns the device to factory settings | □ | Yes | Yes | Yes | Yes | Yes | ||
External Memory / Logs | ||||||||
Micro SD card slot (SDXC up to 512 Gb) | Yes | Yes | Yes | Yes | Yes | Yes | ||
SD card formatting function (FAT32) | Yes | Yes | Yes | Yes | Yes | Yes | ||
USB flash drive: logs, sensor readings, item settings, etc. | Yes | Yes | Yes | Yes | Yes | Yes | ||
Send system log to e-mail: Logs, sensor data, elements settings, etc. | Yes | Yes | Yes | Yes | Yes | Yes | ||
Sensor dump files: save the per-second samples of analog and discrete sensors | Yes | Yes | Yes | Yes | Yes | Yes | ||
Yes | Yes | Yes | Yes | Yes | Yes | |||
Send to FTP server: Logs, sensor data, elements settings, etc. | Yes | Yes | Yes | Yes | Yes | Yes | ||
Maximum amount of log files: 10,000 logs/days = 27 years | Yes | Yes | Yes | Yes | Yes | Yes | ||
Sample rate/period (logs, graphs) | 1 s | 1 s | 1 s | 1 s | 1 s | 1 s | ||
Modem (extension ordered separately) | ||||||||
4G LTE modem: ordered separately. | - | |||||||
Modem modes:
| Gateway / Access / SMS | Gateway / Access / SMS | Gateway / Access / SMS | Gateway / Access / SMS | Gateway / Access / SMS | - | ||
Modem LED: STATUS | Yes | Yes | Yes | Yes | Yes | - | ||
Embedded onboard sensors | VT325tVT225t | |||||||
Temperature sensor: +/- 1 °C PCB temperature. | Yes | Yes | Yes | Yes | Yes | Yes | ||
Power supply voltage sensor: Accuracy (1%) | 1 | Main & Reserve | Main & Reserve | Main & Reserve | Main & Reserve | Yes | ||
LED indication | ||||||||
Ethernet LAN: LINK | Yes | Yes | Yes | Yes | Yes | Yes | ||
Ethernet LAN: ACT | Yes | Yes | Yes | Yes | Yes | Yes | ||
CAN bus: STATUS | Yes | Yes | Yes | Yes | Yes | Yes | ||
System: STATUS (ACT) | Yes | Yes | Yes | Yes | Yes | Yes | ||
System: ERROR (ERR) | Yes | Yes | Yes | Yes | Yes | Yes | ||
System: ALARM | - | Yes | Yes | Yes | Yes | Yes | ||
12V 0.25A outputs: STATUS (e.g. E1, E2) | x2 | x2 | x2 | x2 | x2 | x2 | ||
MODBUS RTU: STATUS | VT485M | VT485M | VT485M | VT485M | VT485M | - | ||
ODSP Reader. | VT485R | VT485R | VT485R | VT485R | VT485R | - | ||
NC/NO/COM Relay (e.g. R1, R2) | x2 | x2 | x2 | - | - | - | ||
Environmental characteristics | ||||||||
Operating temperature: -10 to 80 °C | Yes | Yes | Yes | Yes | Yes | Yes | ||
Storage temperature: –25 to 85 °C | Yes | Yes | Yes | Yes | Yes | Yes | ||
Operating humidity: 0 to 90 %, non-condensing | Yes | Yes | Yes | Yes | Yes | Yes | ||
Storage humidity: 0 to 95 %, non-condensing | Yes | Yes | Yes | Yes | Yes | Yes | ||
Other Features | ||||||||
Installation: | 19” 1U | 19” 1U | 19” 1U | DIN rail, Wall | Desktop | Desktop | ||
Casing: | Sheet metal | Sheet metal | Sheet metal | Plastic | Sheet metal | Plastic | ||
Dimensions (L x W x H) in mm: | 440x44x110 | 440x44x90 | 440x44x90 | L_212.5 H_90.1 D_32.20 | 180x35x80 | 150x29x100 | ||
Weight: | 2 kg | 1,6 kg | 1,5 kg | 0,7 kg | 0,5 kg | |||
External chassis grounding: M4 thread | Yes | Yes | Yes | Yes | Yes | Yes | ||
Web interface (panels) | ||||||||
Dashboard panel: | Yes | Yes | Yes | Yes | Yes | Yes | ||
Overall statistics panel: | Yes | Yes | Yes | Yes | Yes | Yes | ||
System tree panel: sensors and devices displayed in a hierarchy | Yes | Yes | Yes | Yes | Yes | Yes | ||
Dry outputs panel: | Yes | Yes | Yes | Yes | No | Yes | ||
Dry inputs panel: | Yes | Yes | Yes | Yes | Yes | Yes | ||
Event log panel: amount of logs | 500 | 300 | 300 | Yes | 300 | 200 | ||
Logic schemes panel: | Yes | Yes | Yes | Yes | Yes | Yes | ||
Cameras panel: | Yes | Yes | Yes | Yes | Yes | Yes | ||
Map panel: 5 layers | Yes | Yes | Yes | Yes | Yes | Yes | ||
Users panel: | Yes | Yes | Yes | Yes | Yes | Yes | ||
CAN configuration panel: | Yes | Yes | Yes | Yes | Yes | Yes | ||
Graphs panel: | Yes | Yes | Yes | Yes | Yes | Yes | ||
Reset smoke detectors panel: | Yes | Yes | Yes | Yes | Yes | Yes | ||
Preferences panel: Web GUI, Network, Time, Logging, DynDNS, SNMP, RADIUS, FTP backup, VPN Clent, Modbus RTU, GPS, SMTP, Routing | Yes | Yes | Yes | Yes | Yes | Yes | ||
System menu panel: About, Firmware, Export, Support | Yes | Yes | Yes | Yes | Yes | Yes | ||
List of latest sent SMS messages: | 500 | 200 | 200 | Yes | 150 | 200 | ||
Analog sensor power reset: resets smoke sensors | Yes | Yes | Yes | Yes | Yes | Yes |
● Built-in □ None ♦ Extension possible ◊ Not extendable