Device description | |||||
---|---|---|---|---|---|
Description: | Switchable | Switchable | |||
Device management: Web, SNMP, manual using SMS, 4G LTE | Yes | Yes | |||
Sensor access: Three-level by login | Yes | Yes | |||
Interface and supported protocols | |||||
LAN: Ethernet 10/100 Mbit | Yes | Yes | |||
OS: Linux | 3.10 | 3.10 | |||
Interface: Any browser | Yes | Yes | |||
Memory RAM: | 64Mb | 64Mb | |||
CPU Speed: | 300 MHz | 300 MHz | |||
Total CPU cores: | 1 | 1 | |||
Clock: Built-in clock | Yes | Yes | |||
Timer: Built-in watchdog | Yes | Yes | |||
The maximum amount of sensors: physical sensors, dry contacts, relays | |||||
The maximum amount of elements: notifications, triggers, timers, logic, sensors, dry contacts, SNMP Get, SNMP Trap, Dial task, and other elements | |||||
Networking / Protocol support | |||||
LTE Gateway mode: Internet access (routing for internal network) (modem ordered separately) | Yes | Yes | |||
LTE Access mode: Internet access over LTE (modem ordered separately) | |||||
Network protocols: DHCP; HTTP; HTTPS; SNMP v1, v2c, v3; SMTP; FTP; Syslog; TLS; | Yes | Yes | |||
Modbus RTU (only with USB converter) | Yes | Yes | |||
Modbus TCP / IP | Yes | Yes | |||
Static routing | |||||
Dynamic DynDNS | Yes | Yes | |||
Access via RADIUS server | Yes | Yes | |||
VPN: secure data communications; secure change of connection between LTE and LAN | Yes | Yes | |||
SSL installation | Yes | Yes | |||
NTP server | Yes | Yes | |||
Alerts / Notifications | |||||
Alert types: E-mail, FTP log, Syslog, SMTP, SNMP Traps, SMS (Modem is ordered separately), Web-to-SMS, | Yes | Yes | |||
A maximum number of "mail to" recipients in an E-mail notification: | 10 | 10 | |||
A maximum number of "SMS to" recipients in an SMS notification: also the maximum amount of phone numbers | 10 | 10 | |||
Virtual sensors | |||||
Ping: Built-in pinging | Yes | Yes | |||
IP cameras: Connect the IP MJPEG camera with a proxy via the master module. Only view, no record. | 4 | 4 | |||
Get SNMP: Read data from external equipment via SNMP PDU GET (v1/2c) | Yes | Yes | |||
Logic schemes: Used to specify automatic actions to events that occur in the system. | Yes | Yes | |||
Timers: Allows you to plan the events in the system. | Yes | Yes | |||
Triggers: Generate events in the system if logic is triggered. | Yes | Yes | |||
SNMP traps | Yes | Yes | |||
Virtual Math element (combine several sensor data and calculate new data) | Yes | Yes | |||
Logic schemes | Yes | Yes | |||
Modbus TCP/IP: read/write | Yes | Yes | |||
Power | |||||
Power supply: | 110-240V 50-60 Hz | 110-240V 50-60 Hz | |||
Input: | C14 10A | C20 16A | |||
Fuse: | 10A | 16A | |||
Outputs: | 4 | 8 | |||
Power consumption: | 10W | ||||
Total power load: | 2.4 kW | ||||
Power measurement: | No | No | |||
Outputs: Bistable relays with indication on the front panel | 4 | 8 | |||
Outputs | |||||
Relays outputs: 12V 0.25A | 2 | 2 | |||
Bistable relays: with indication on the front panel | x4 Max 10A | x8 Max 10A | |||
Sockets: | 4 IEC 320 C13 | 8 IEC 320 C13 | |||
Inputs | |||||
Max. dry contact inputs (contact closures/digital outputs) | 2 | 2 | |||
Sensors: Analog sensors RJ12 (Analog port: 6P6C for connection of an analog sensor. (extendable using CAN bus) | 2 ports | 2 ports | |||
1 x1 CAN bus: RJ12 for connecting up to 12-20 CAN devices per bus. See "CAN devises connection". | 1 | port: Max number of sensors Use CAN-12V-1A for connecting more than 12 devices. | 20 | 20 | |
Max. dry contact inputs (contact closures/digital inputs) Extadable using CAN bus and Dry contacts unit | 2 built-in & extadable | 2 built-in & extadable | |||
Other connectors | |||||
Ethernet port: 10/100Mbit | Yes | Yes | |||
Mini USB AB: USB 2.0 HS | Yes | Yes | |||
Switch Normal / Recovery: returns the device to factory settings | □ | Yes | |||
External memory / Logs | |||||
USB flash card slot: | Yes | Yes | Scalability (units are drive: logs, sensor readings, item settings, etc. | Yes | Yes |
Send system log to e-mail: Logs, sensor data, elements settings, etc. | Yes | Yes | |||
Sensor dump files: save the per-second samples of analog and discrete sensors | Yes | Yes | |||
Yes | Yes | ||||
Send to FTP server: Logs, sensor data, elements settings, etc. | Yes | Yes | |||
Maximum amount of log files: 10,000 logs/days = 27 years | Yes | Yes | |||
Sample rate/period (logs, graphs) | 1 s | 1 s | |||
Modem (extension ordered separately) | |||||
Extension unit: Allows increasing the number of sensors in the system. | CAN | CAN | |||
Modem: Internal | LTE | LTE | |||
Environment 4G LTE modem: ordered separately. | |||||
Modem modes:
| Access / SMS | Access / SMS | |||
Embedded onboard sensors | |||||
Temperature sensor: +/- 1 °C Case temperature. | Yes | Yes | |||
Environmental characteristics | |||||
Operating temperature: 0 to 60 °C | Yes | Yes | |||
Storage temperature: –25 to 85 °C | Yes | Yes | |||
Operating humidity: 0 to 90 %, non-condensing | Yes | Yes | |||
Storage humidity: 0 to 95 %, non-condensing | Yes | Yes | |||
Other Features | |||||
Installation: | 19” | 19” | |||
Dimensions (L x W x H) in mm: | 440*44*80 | 440*44*80 | |||
Weight: | 1,3 kg | 1,5 kg | |||
LEDs: System status, CAN, 12V outputs E1 and E2, System Error | 4 | 8 | |||
LEDs: Orange for relays | 4 | 8 | |||
Embedded sensors | VT604 | VT608 | |||
Temperature sensor: +/- 1 °C Case temperature. | |||||
External chassis grounding: M4 thread | Yes | Yes | |||
Web interface (panels) | |||||
Dashboard panel: | Yes | Yes | |||
Overall statistics panel: | Yes | Yes | |||
System tree panel: sensors and devices displayed in a hierarchy | Yes | Yes | |||
Dry inputs panel: | Yes | Yes | |||
Event log panel: | 200 | 200 | |||
Logic schemes panel: | Yes | Yes | |||
Cameras panel: | Yes | Yes | |||
Map panel: 5 layers | Yes | Yes | |||
Users panel: | Yes | Yes | |||
CAN configuration panel: | Yes | Yes | |||
Graphs panel: | Yes | Yes | |||
Reset smoke detectors panel: | Yes | Yes | |||
Preferences panel: Web GUI, Network, Time, Logging, DynDNS, SNMP, RADIUS, FTP backup, VPN Clent, GPS, SMTP, Routing | Yes | Yes | |||
System menu panel: About, Firmware, Export, Support | Yes | Yes | |||
List of latest sent SMS messages: | 100 | 100 | |||
Analog sensor power reset: resets smoke sensors | Yes | Yes |