Function and purpose

The VT109 is designed for light alarms in monitoring systems. It can be connected to both 12V DC, 0.25A electronic relay outputs of Vutlan monitoring systems to provide a visual alert when an alarm event is triggered.

Can be used with 3rd party controllers.

Use cases

Use Cases:

  • Data Centers: Provide an immediate alert for overheating, water leaks, or power failures.

  • Industrial Facilities: Notify operators of system malfunctions or critical events in real time.

  • Relay Output Connection: Operates on 12V DC, 0.25A, making it compatible with various systems requiring local alarm solutions.

Technical specifications

Function & Purpose

Description

Device type:

12V DC light alarm

Rated voltage:

12V DC, 70mA

Output:

Red, Yellow and Green Lights

 

 

Envrironmental

Description

Operating temperature:

Min. -50 °C - Max.105 °C

Operating humidity:

Min. 5% - Max. 95% (Non-Condensing)

IP rating standard:

IP54

 

 

Power

Description

Power consumption:

100mW

 

 

Mechanical

Description

Weight:

150g

Dimensions:

∅50 x 310 mm (550mm with support)

Mounting:

Desktop, surface, enclosure rack or wall

Cable length:

2 meters

Case:

ABS plastic, red, yellow, green

 

 

General

Description

Manufactured in:

Made in the EU

HS code:

94053100

GTIN:

8588009886747

Warranty:

3 months

Dimensions

VT109 light flash alarm alert tower by Vutlan dimensions.webp

Installation (rack stand)

The rack stand bracket is included with the VT109 light alert tower.

  1. Mount the tube, rack stand base.

  2. Put the RJ9 connector through the tube of the rack stand bracket.

  3. Plug the RJ9 connector into the RJ9 port inside the light tower’s bottom.

  4. Screw the rack stand bracket into the light tower’s bottom base.

VT109 light flash alarm alert tower by Vutlan-02.webp
  1. Mount the rack stand bracket onto a surface or a rack and connect the 3-pin green power connector into Vutlan monitoring unit’s 12 V DC power outputs.

VT109 light flash alarm alert rack tower to environmental monitoring unit by Vutlan.webp

Power cable pin out

VT109 light tower is supplied with (RJ9 4P4C) to (15EDGK 03P 3.81mm) power cable. Use the following diagram for prolonging the cable or making your own.

VT109 light flash alarm alert tower power cable pinout by Vutlan.webp

Connecting 12V devices to Vutlan monitoring systems

See page https://vutlan.atlassian.net/wiki/spaces/DEN/pages/71181064/Connecting+12V+devices+to+12V+outputs

12V relay configuration

VT109 light tower connects to 12V DC outputs. First, we need to configure the individual relay outputs of the unit.

For this example, we will use VT335t

Relay outputs on different Vutlan units may vary. When connecting the VT109 light alert tower, relay outputs “Relay 1” and “Relay 2” connections may be reversed. This means that Red and Yellow may be reversed. So please make the configurations accordingly.

VT335t panels v3.0.webp

Cable wires

VT335t 12V DC outputs

Light tower alert color

Cable wires

VT335t 12V DC outputs

Light tower alert color

 

Red

Relay E1

Yellow alert

 

 

Black/Green

Relay E1 + Relay E2

Green alert

 

White

Relay E2

Red Alert

1) Log in to the web interface of the monitoring system

2) System tree menu >> Power 12V 0.25A >> Choose relay

image-20260206-095659.png

3) By default, the names are Power-1 and Power-2. Rename them accordingly, set the initial state, and set the pulse duration time in seconds to a specific period.

Let’s rename Power-1 to “Relay E1 Yellow alert”.

Let’s rename Power-2 to “Relay E2 Red alert”.

image-20260206-095638.png

Configuring the light tower alerts using logic

Example 1: Normal > Green, Warning> Yellow, Alert > Red

For this example, we will use the VT109 light tower to flash a light according to the status of a Group of sensors.

  1. Let’s create a group of sensors. System tree >> + “add element” >> Name the group “Sensor group 1” >> Elements tab >> add sensors to the group.

image-20260206-102248.png

If one of the sensors in the group is in the Alert state. The whole group will be in the Alert state, because Alert state has the highest priority.

If one of the sensors in the group is in the warning state, and no other sensor is in the alert state, the group is in the warning state.

If all sensors in a group are in the Normal state, the group is in the Normal state.

We want to achieve the following:

 

Group state

 

Relays

Light tower color

 

Group state

 

Relays

Light tower color

IF

Normal

THEN

Relay 1 = On

Relay 2 = On

Green

IF

Warning

THEN

Relay 1 = On

Relay 2 = Off

Yellow

IF

Alarm

THEN

Relay 1 = Off

Relay 2 = On

Red

  1. Go to Logic Schemes panel >> Add x3 logic schemes

image-20260206-103208.png
image-20260206-103227.png
image-20260206-103243.png

Package includes

The following page included: VT109 package content

Package includes:

 

Package content

Description

Quantity

 

Package content

Description

Quantity

1

VT109 light alert alarm flash signal tower for monitoring unit by Vutlan.webp

Light tower

1 pcs

2

VT109 light alert alarm flash signal tower for monitoring unit (surface mount bracket) by Vutlan.webp

Surface mount bracket kit

x1 Tube

x1 base

3

VT109 light alert alarm flash signal tower for monitoring unit (power cable) by Vutlan.webp

Power cable

RJ9 4P4C

to

15EDGK 3P 3.81mm

x1

4

VT109 light alert alarm flash signal tower for monitoring unit (wall mount bracket) by Vutlan.webp

Mount bracket kit



x2 Bolts

x1 Washer

x1 L bracket




Copyright of:

Vutlan s.r.o.

43 ul.Svornosti, 821 06 Bratislava,

Slovak Republic